MAIN CHARACTERISTICS
OPERATIONS PRIOR TO SWITCHING ON
The unit is factory-set. The basic settings can be modied individually according to personal needs.
Make sure the tank is lled with water before switching on.
After inserting the power plug and, possibly, after activation of a switch installed in the place, the heat pump is ready
for operation.
SWITCHING ON
BASIC FUNCTIONS
The unit is activated if the following basic functions are dened:
- Operation mode
- Set Point
The activation method and operating principle of these functions is described below:
Selection and description of operation mode
Press the mode button to select from various operation modes available:
HYBRID HEATING - ECO HEATING – AUTO HEATING – VACATION
1. HYBRID HEATING The unit heats the water tank using the
compressor and the heating element or boiler at the same time.
A heating element activation delay with respect to compressor
activation can be set. Below a certain air temperature it is
possible to ensure that only the heating element is activated
(Fig.3).
2. ECO HEATING The unit heats the water tank using only the
compressor. Below a certain air temperature it is possible to
ensure that only the heating element is activated (Fig.4).
Fig.1
Fig.2
Fig.3
Fig.4
SWITCHING ON
When switched on, the unit activates all the display segments,
subsequently showing the controller release. After 15 seconds
it is in off mode, displaying the icons shown opposite (Fig.2).
Press the button for 05 seconds to switch the unit on.
The display shows the water temperature, which part of the tank
it refers to and the active operation mode.