12
MAIN CHARACTERISTICS
Table of displayable parameters
Settable parameters table
Parameter
code
Description of parameter Status display Meaning
S01 Remote switch status CL\OP Closed\Open
S02 Overheating switch status CL\OP Closed\Open
S03 Low pressure switch status CL\OP Closed\Open
S04 High pressure switch status CL\OP Closed\Open
S05 Heating element or boiler switch status CL\OP Closed\Open
S06 Water ow switch status CL\OP Closed\Open
t01 Ambient temperature reading current °C
t02 Tank bottom temperature reading current °C
t03 Tank upper part temperature reading current °C
t04 Exchanger temperature reading current °C
t05 Compressor inlet temperature reading current °C
t06 Solar probe temperature reading current °C
O01 Compressor status ON\OFF On\Off
O02 Heating element or boiler status ON\OFF On\Off
O03 4-way valve status ON\OFF On\Off
O04 Fan max. speed status ON\OFF On\Off
O05 Solar pump\recirculating pump\fan min. speed status ON\OFF On\Off
O06 Solar pump\recirculating pump\activation indicator status ON\OFF On\Off
O07 Electronic valve position No. steps
Position between
0 and 500
Parameter
code
Description of parameter Default value
Range of settable
values
d01 Defrost start temperature -3°C -30 ~ 0°C
d02 Defrost end temperature 13°C 0 ~ 30°C
d03 Time between two defrosts 45 min 30 ~ 90 min
d04 Defrost max. duration 8 min 1 ~ 20 min
g02 Disinfection cycle duration 0 min 0 ~ 90 min
g03 Disinfection cycle start time 0 h 0 ~ 23 h
g04 Days between disinfection cycles 7 D 7 ~ 99 D
e01 Type of electronic valve regulation 1 0-Manual\1-Auto
e03 Electronic valve initial step position 350 0 ~ 500
n10 Storage tank base temperature for solar pump stop 70°C 50 ~ 90°C
r06 Heating elements activation delay 200 min 0 ~ 450 min
The following tables give the values of the various parameters.
Notes:
- If the ON\OFF button is pressed during parameter setting, the unit returns to the main menu without saving the
settings.
- If no buttons are pressed within 20 seconds during the setting-display phase, the system saves the settings and
returns to the main menu.